Low smoke and zero halogen cables are suitable for environments that require low smoke and zero halogen under fire conditions. Equipment that can be used in kitchens, offices, and indoor humid environments. It is also suitable for cooking and heating equipment when the cable is not in contact with hot components or thermal radiation. Not suitable for high-temperature environments (such as lighting equipment), cannot be used outside buildings, industrial or agricultural buildings, power tool connections.
Conductor: Stranded bare copper or tinned copper in accordance with VDE 0281 Part 5, HD21 BS 6360 cl. 5, IEC 60228 cl. 5, HD 383
Insulation: Thermoplastic mixture TI6 insulation in accordance with DIN VDE 0281
Color recognition: Color coding follows VDE-0293-308
Sheath material: halogen-free thermoplastic mixture TM7 sheath
Application standards: HD21.14 S1, VDE-0281 Part-14, VDE 0482-332-1-2, CEI 20-20/14, CEI 20-35 (EN60332-1), CEI 20-37 (EN50267), EN50363, CE low-voltage 73/23/EEC& Directive 93/68/EEC
Features:Ultra fine conductor, soft and small bending angle; Capable of withstanding certain mechanical external forces
Smoke density EN 50268/IEC 61034
Gas corrosiveness follows EN 50267-2-2, IEC 60754-2 flame retardancy test follows EN 50265-2-1, IEC 60332.1 complies with EU harmonized standards
Compliance with certification:RoHS CE
· Rated voltage: | 300/300V (H03Z1Z1-F) |
Test voltage: | 2000V (H03Z1Z1-F) in accordance with DIN VDE 0281 Part 2 HD21.2 |
·Minimum bending radius | |
Fixed laying: | five × D (cable outer diameter) |
Mobile installation: | eight × D (cable outer diameter) |
· Temperature range | |
Fixed laying: | -20 to+70 ℃ |
Mobile installation: | -5 to+70 ℃ |